Error 204.x First can-body contaminated


Description

Energy:
During calibration the contamination must not respond before or on the first can body. During calibration the threshold is 9.0 volt of the filtered voltage between the roller heads.
Pulsar:
The contamination monitor has responded on the Pulsar channel on the first can body.

Remedy

  • If the welding current has been strongly increased or material quality/machine setting has changed, the monitor must be readjusted. 
  • If the first can body was an overlacquered sheet, repeat calibration. 
  • Contaminated wire must be cleaned. 
  • Check voltage contacts. 
  • Check mechanical welding settings. 
  • Measure (filtered voltage) in the +800 box at measuring card. 
  • Request Description “Weld Monitor SWM-2: Sporadic Contamination” from Soudronic. 
  • Energy node with new UC3 Coldfire hardware (745-09313/00 or 745-09314/00): the voltage measurement signal can be too high for the AFB 108-LT, Soucan 100-LT or PMB machines. In this case, you can set parameter EnergyUseExtendedValueRange = TRUE. Energy card 745-01816/101 can be used for energy node with UC2 hardware (745-09013/04). 
  • Measure the signals of the energy channel
  • Check the welding loop, Pulsar