Views:

Measure the signals of the energy channel


Description

Insulation check of monitor taps

Resistance measuring at the test taps in the monitor box (+800):

Measuring point in monitor box (+800)ValueRemarks
Unfiltered voltage red - black1 ohmTaps not insulated
Unfiltered voltage red - machine ground1 ohmTaps not insulated
Unfiltered voltage black - machine ground1 ohmTaps not insulated
Unfiltered voltage red - black337 ohmTaps insulated
Unfiltered voltage red - machine ground212 ohmTaps insulated
Unfiltered voltage black212 ohmTaps insulated

To measure the resistance at the monitor taps, the cable at +800-X1 must be disconnected:

Measuring point at plug X1ValueRemarks
X1:Pin1 - upper monitor tap1 ohmTaps insulated
X1:Pin1 - lower monitor tap1 ohmTaps insulated
X1:Pin2 - upper monitor tap1 ohmTaps insulated
X1:Pin2 - lower monitor tap1 ohmTaps insulated
X1:Pin2 - Z-bar1 ohmTaps insulated

 

All machine errors