Check welding transformer, Pulsar
Description
- Check screws from Pulsar to welding transformer.
- Check transformation ratio of welding transformer in control unit.
- Carry out system identification.
- Contamination also in short circuit?
- Yes
- No
Continue with the next step.
- Switch welding monitor off for troubleshooting
- Check contamination settings. Too sensitive? Execute Monitor Setup on the Unicontrol Monitor Setup and check level of sensibility.
- Q1 values over 10% are not acceptable!
- Check mechanical settings, check welding pressure, does the spring run perfectly?
- Check sheet quality.
- Problem solved?
- Yes
Check during production.
- No
Not a Pulsar problem!