Views:

Check roller head, Pulsar


Description

  1. Welding current or frequency too high? 

- Yes, maybe 

Proceed with step 5. 

- No 

Proceed with step 2. 

  1. Check copper braids on pendulum roller head (corrosion of contacts, screws). 
  2. Check roller head according to document:775.99600230/00 
  3. Problem solved? 

- Yes 

Check during production. 

- No 

Perform PulsarDiag measurements with “CurveForm” template and in consultation with TEE. 

  1. Sinusoidal waveform, halve welding current and frequency. 
  2. Contamination? 

- Yes 

Perform PulsarDiag measurements with “CurveForm” template and in consultation with TEE. 

- No 

Progressively test until reasonable production values are achieved. If necessary change transformer tap to increase the supply voltage. 
Check during production. 

All machine errors