Check welding transformer, Pulsar
Description
- Check screws from Pulsar to welding transformer.
 - Check transformation ratio of welding transformer in control unit.
 - Carry out system identification.
 - Contamination also in short circuit?
 
- Yes
- No
Continue with the next step.
- Switch welding monitor off for troubleshooting
 - Check contamination settings. Too sensitive? Execute Monitor Setup on the Unicontrol Monitor Setup and check level of sensibility.
 - Q1 values over 10% are not acceptable!
 - Check mechanical settings, check welding pressure, does the spring run perfectly?
 - Check sheet quality.
 - Problem solved?
 
- Yes
Check during production.
- No
Not a Pulsar problem!
		