Error 102.x Leading end of can bodies shifted


Description

The leading end is not at the same position relative to the machine cycle signal as during calibration.
± 2* Can Jitter corresponds to ±12% error tolerance

Remedy

  • After every change of the production parameters (conversion of welding machine or measuring lens of the temperature measuring system), the monitor must be calibrated again. 
  • If the leading end of the first can body is not properly welded, the welding geometry must be checked and the calibrating tool reset. 
  • If the leading end is damaged (bent-back corners), the overlap irregular, check the passage of the sheets through the welding machine. 
  • Check if the wire is oxidized or contaminated. 
  • Clean or redress groove of pendulum roller head. 
  • If the clock signal is faulty, check wiring and remedy error. 
  • Measure the signals of the energy channel. 

All machine errors