Error 102.x Leading end of can bodies shifted
Description
The leading end is not at the same position relative to the machine cycle signal as during calibration.
± 2* Can Jitter corresponds to ±12% error tolerance
Remedy
- After every change of the production parameters (conversion of welding machine or measuring lens of the temperature measuring system), the monitor must be calibrated again.
- If the leading end of the first can body is not properly welded, the welding geometry must be checked and the calibrating tool reset.
- If the leading end is damaged (bent-back corners), the overlap irregular, check the passage of the sheets through the welding machine.
- Check if the wire is oxidized or contaminated.
- Clean or redress groove of pendulum roller head.
- If the clock signal is faulty, check wiring and remedy error.
- Measure the signals of the energy channel.