Views:

606.x Unit4 Overcurrent


Description

If the output current of the PULSAR reaches too high a value, it is switched off because of overcurrent to protect the roller heads.
In case of Pulsar15x, the threshold is at 400A peak current and for Pulsar30x, at 550A.

Remedy

With a PULSAR xx1 device:

  • the welding frequency can be increased.
  • the welding current can be reduced.
  • the DC link voltage of the PULSAR can be reduced.
  • the line input voltage can be checked.
  • Check the welding transformer, Pulsar.

With a PULSAR xx4 device:

All machine errors