Views:

769.x Energy: Short circuit voltage too low


Description

Energy monitor
During the series start-up of the monitor, the voltage is measured in short-circuit current. This value must be higher than a lower limit value. If this value is not reached, an error message appears.

Remedy

  • Check voltage contacts.
  • +800Box: measure unfiltered voltage in the measuring card. This voltage must be > 0.2 volt
  • +800 Box: measure the filtered voltage in the measuring card. This voltage must be > 0.2 volt
  • Check connector +800:X1.
  • Check the digital input. 
  • Measure the signals of the energy channel. 

All machine errors