Error Code C3h on Linmot control unit and BF LED on PLC red
Some Beckhoff i/o terminals are not active and status LEDs are off, control does not respond to commands
The oven triggered a line stop at the welding machine.
The powder system is in test mode.
A jam has been detected on the oven conveyor. After more than 2.5 can bodies this jam is detected.
Jam detected on the EAC conveyor. Jam is detected when the sensor is covered for more than 2.5 can-body lengths.
The conveyor system has reported a fault after the EAC
The vacuum has not been switched off. Just before the sheet reaches the first for the two pull-in rollers the vacuum must be switched off.
The can-body conveyor stops before all can bodies have passed through the eject station.
The pressure of the combustion air (primary air) in the oven is too low (3m burner 10 to 70 mbar, 1.5m burner 7 to 90 mbar).
The process air pressure (secondary air) in the oven is too low.
Lifting table The top-most position of the sheet stack is regulated automatically.
The external machine STOP circuit is interrupted.
Communication (RS232) with HVS card or powder monitor hardware in lower arm has been interrupted.
The powder firmware version is not compatible with the Unicontrol node software.