Views:

924.x Energy counter not working


Description

Energy and power measurement
During the energy measurement or power measurement, no test signals are present.
Missing test signals trigger a warning. This warning is cleared when test signals are received again.

Remedy

  • Electrical energy: Check consumption measurement pulse. A pulse must be generated at least every 60 seconds. This equates to energy of min. 6 kWh.
  • Air consumption: Check analog consumption measurement signal. The minimum analog value must be higher than 0.1 volt.

All machine errors