922.x HvDiagnostics


Description

HV CPF 400 powder application diagnostics
An error occurred during diagnostics on the high voltage-system.

Remedy

  • Electrode dirty; clean electrode.
  • Cascade not fully connected; attach cascade correctly.
  • Electrode holder defective; replace electrode holder.
  • High-voltage duct insufficiently greased; grease the high-voltage duct.
  • High-voltage duct missing or defective; replace high-voltage duct.
  • Cascade chamber dirty; replace cascade.
  • Cascade defective; replace cascade.
  • High-voltage duct defective; replace high-voltage duct.
  • Check wiring.
  • Cable defective; replace cable.
  • Cascade defective; replace cascade.
  • Cable defective; replace cable.
  • HV generator box A120 defective; replace box A120.
  • Measuring adapter defective; replace measuring adapter.
  • Update the UNICONTROL application software.
  • High-voltage measuring adapter missing. Attach high-voltage measuring adapter.
  • Check electrode purge air.