922.x HvDiagnostics
Description
HV CPF 400 powder application diagnostics
An error occurred during diagnostics on the high voltage-system.
Remedy
- Electrode dirty; clean electrode.
- Cascade not fully connected; attach cascade correctly.
- Electrode holder defective; replace electrode holder.
- High-voltage duct insufficiently greased; grease the high-voltage duct.
- High-voltage duct missing or defective; replace high-voltage duct.
- Cascade chamber dirty; replace cascade.
- Cascade defective; replace cascade.
- High-voltage duct defective; replace high-voltage duct.
- Check wiring.
- Cable defective; replace cable.
- Cascade defective; replace cascade.
- Cable defective; replace cable.
- HV generator box A120 defective; replace box A120.
- Measuring adapter defective; replace measuring adapter.
- Update the UNICONTROL application software.
- High-voltage measuring adapter missing. Attach high-voltage measuring adapter.
- Check electrode purge air.