922.x HvDiagnostics
Description
HV CPF 400 powder application diagnostics
An error occurred during diagnostics on the high voltage-system.
Remedy
- Electrode dirty; clean electrode.
 - Cascade not fully connected; attach cascade correctly.
 - Electrode holder defective; replace electrode holder.
 - High-voltage duct insufficiently greased; grease the high-voltage duct.
 - High-voltage duct missing or defective; replace high-voltage duct.
 - Cascade chamber dirty; replace cascade.
 - Cascade defective; replace cascade.
 - High-voltage duct defective; replace high-voltage duct.
 - Check wiring.
 - Cable defective; replace cable.
 - Cascade defective; replace cascade.
 - Cable defective; replace cable.
 - HV generator box A120 defective; replace box A120.
 - Measuring adapter defective; replace measuring adapter.
 - Update the UNICONTROL application software.
 - High-voltage measuring adapter missing. Attach high-voltage measuring adapter.
 - Check electrode purge air.
 
		