606.x Relay driver X9 error


Description

The digital outputs on plug X9, which are partially used to activate the two contactors K1 and K2, are monitored for short circuit and thermal overload. This error can also occur as a result of a defective output driver.

Remedy

  • Check contactor, valve or load for short circuit or interruption.
  • Check digital outputs/ replace Pulsar.