606.x DC voltage shorted
Description
When loading the link via the softstart, the DC link voltage is measured after K1 is switched on. If the link has not reached 20% of the peak network voltage after one second, this error is triggered.
Remedy
- Check control/wiring/function of K1
- Replace Pulsar