893.x Peltier element defective or wiring fault
Description
OSS outside seam lacquering with LTC
The temperature controller PID status is at the upper or lower limit. The temperature cannot be regulated.
Remedy
- Check power supply to Peltier element.
- Check wiring of Peltier element.
- Replace Peltier element.