Views:

884.x LTC Device status error


Description

A device fault has been detected at the LTC of the OSS outside seam lacquering system.
A line stop is triggered at the welding machine.

Remedy

  • The error number appears in brackets in the error message, e.g., (134). Ask Soudronic for the specific error with this number.

    Error (1...10): processor error 
    Error (11...12): HMI error 
    Error (20...29): parameter system error 
    Error (30...37): power supply problems 
    Error (50...52): flash memory error 
    Error (53): communication buffer overflow 
    Error (60...61): device temperature, hardware error 
    Error (100...111): power output error 
    Error (120...123): current measurement error 
    Error (130...139): object temperature measurement error 
    Error (140...144): sink temperature measurement error 
    Error (150...153): object temperature measurement error 
    Error (170...173): autotune error 
     
  • Activate the Trace functions LtcInfo and LtcErrorInfo.