884.x LTC Device status error
Description
A device fault has been detected at the LTC of the OSS outside seam lacquering system.
A line stop is triggered at the welding machine.
Remedy
- The error number appears in brackets in the error message, e.g., (134). Ask Soudronic for the specific error with this number.
Error (1...10): processor error
Error (11...12): HMI error
Error (20...29): parameter system error
Error (30...37): power supply problems
Error (50...52): flash memory error
Error (53): communication buffer overflow
Error (60...61): device temperature, hardware error
Error (100...111): power output error
Error (120...123): current measurement error
Error (130...139): object temperature measurement error
Error (140...144): sink temperature measurement error
Error (150...153): object temperature measurement error
Error (170...173): autotune error
- Activate the Trace functions LtcInfo and LtcErrorInfo.