853.x Discon pump switch off: Circuit 2 too low
Description
The DISCON pump can be switched off when cooling circuit 2 is disabled. The Discon pump is directly controlled by the emergency stop power supply, hence an emergency stop error message must be generated.
Remedy
- The Discon pump monitoring is activated with parameter $WelderDisconPumpSwitchOff = TRUE.
- The Discon pump is switched off if the machine is not producing and there is no cooling in cooling circuit 2 for at least one minute.