803.x Destacker: Additional sheet detected
Description
Feeder/rollformer: sheet flow monitoring
The flow of the sheet from the feeder to the rollformer can be monitored. This monitoring is only active if "Dynamic monitoring double-sheet deflector" has been selected in the options.
The following is checked:
- Single sheet from feeder to rollformer: ARS sheet detector detects the sheet.
- Ejection of a detected double sheet: ARS sheet detector does not detect any sheet.
- The single sheet detector functions when a sheet is missing: ARS sheet detector detects a missing sheet.
Remedy
Detected double sheet is not ejected:- Check functionality of the double-sheet deflector.
- Check ARS sheet detector.
- Check rounding speed.
- Change the double-sheet monitor option from dynamic to static.
- Check the digital input.
- Check ARS sheet detector.
- Check rounding speed.
- Change the double-sheet monitor option from dynamic to static.
- Check the digital input.
- Check feeder single sheet sensor.
- Check rounding speed.
- Change the double-sheet monitor option from dynamic to static.
- Check the digital input.