Views:

802.x Destacker: Double sheet not ejected


Description

Feeder/rollformer: sheet flow monitoring
The flow of the sheet from the feeder to the rollformer can be monitored. This monitoring is only active if "Dynamic monitoring double-sheet deflector" has been selected in the options.
The following is checked:

  • Single sheet from feeder to rollformer: ARS sheet detector detects the sheet.
  • Ejection of a detected double sheet: ARS sheet detector does not detect any sheet.
  • The single sheet detector functions when a sheet is missing: ARS sheet detector detects a missing sheet.

 

Remedy

Detected double sheet is not ejected:
  • Check functionality of the double-sheet deflector.
  • Check ARS sheet detector.
  • Check rounding speed.
  • Change the double-sheet monitor option from dynamic to static.
  • Check the digital input. 
Sheet is not transported:
  • Check ARS sheet detector.
  • Check rounding speed.
  • Change the double-sheet monitor option from dynamic to static.
  • Check the digital input. 
Additional sheet was detected in the rollformer:
  • Check feeder single sheet sensor.
  • Check rounding speed.
  • Change the double-sheet monitor option from dynamic to static.
  • Check the digital input. 

All machine errors