Views:

761.x Pressure out of tolerance


Description

Powder Soucoat equipment with pressure control
The pressure in the powder feed and in the powder recycling systems is monitored by means of pressure sensors.

Remedy

Powder feed
  • In case of pressure drop:
    • Check/clean sensor filter.
    • Check the function of the powder gate.
    • Check the powder feed injector in the CPF.
    • Check the minimum powder level in the CPF.
    • Check the powder tubes from the CPF to the spray head.
    • Check the proportional valves.
    In case of increase in pressure:
    • Check/clean the powder tubes from the CPF to the spray head.
    • Check/replace the injector nozzle.
Powder recycling:
  • In case of pressure drop (more vacuum):
    • Check/clean the powder tubes from the spray head to the CPF.
    In case of increase in pressure (less vacuum):
    • Check/clean sensor filter.
    • Check the powder tubes from the spray head to the CPF.
General:
  • Check powder application and suction. If OK, calibrate again the powder pressure monitor.
  • Set the limits of powder pressure monitor.
  • Check the wiring to the control unit.
  • Replace the analog card.