743.x Rollformer open/close: Mechanically locked
Description
Open/close the rollformer.
The rollformer needs to be opened or closed. The condition "Rollformer closed" or "Rounding station down" is not fulfilled.
Remedy
The rollformer cannot be opened or closed.Check the following conditions:
- Open both rollformer locks (input 0 V).
- Close lower rounding station (input 24 V).
- Set automatic sheet feeding robot in parking position (input 24 V).
- Protective door on feeder, right, is closed (input 24 V).
- Protective door on feeder, left, is closed (input 24 V).
- Soucan 800/1000 CO2: all five feeder protective doors closed (input 24 V).
- Front protective doors and conveyor protective doors (both at AFB) are open (input 0 V).
- Soucan 2075 COX: front left protective door closed (input 24 V).
- The front protective doors and the conveyor protective doors can be overridden by setting parameter $WelderIgnoreFrontDoorToOpenRollformer = TRUE.
- Check the digital input.