Views:

680.x Plate roll at weld station is blocked


Description

Soutube plate roller monitoring
The plate rollers in the welding station are monitored for a minimum speed ($SoutubePlateRollsMinSpeed). If this speed is not reached, this error message is displayed and production stopped.
This monitoring is active during production and set up with laser.

Remedy

  • Check plate rollers are running freely.
  • Check sensors on the plate rollers.
  • Plate roller monitoring can also be switched off in the GCC.
  • Check the digital input. 

All machine errors