Views:

671.x Powder monitor: Calibration out of tolerance


Description

Powder monitor temperature calibration
The specified setpoint value could not be reached.

Remedy

  • Fit reference reflector.
  • Clean sensor with pure alcohol.
  • Change reference value of temperature calibration.
  • Replace the powder monitor electronic components.

All machine errors