597.x Line: Can jam on erector
Description
Can-body flow at can upender is monitored.
Remedy
- Clear can-body jam at can upender.
 
Can upender right after the welding machine
- Input A014:In8 or A014:Analog In2 must be "OFF" without can bodies.
 - The defined "Monitoring distance to can upender" is too short.
 - Check sensors A014:In1 at the ejection.
 
Can upender after the oven.
- Inputs A056:In3 and A056:In4 must be "OFF" without can bodies.
 - Distance "LineDistanceBetweenInletAndBuffer2" is too short.
 - Check sensors A056:In1 and A056:In2 at oven run-out
 
		