588.x Analog values too small
Description
Wire profiler and wire chopper
The distance from the sensor to the skid is measured at the wire profiler and wire chopper. This error is displayed if this distance is less than the analog value of 0.1 volt, .
Remedy
- Is the analog sensor supplied?
- Is the sensor connected on the analog input of the Unicontrol unit?
- Measuring the voltage in standby.
- Optimize the mechanical adjustment of the sensor.
- Replace the analog card.