423.x Powder: Measured current out of working range


Description

Current for powder coating is too low.
The measured power in the Soucoat hardware is less than 70% of the specified setpoint.

Remedy

  • Clean coating chamber and electrodes.
  • Check the electrode purge air.
  • If there is no purge air: check purge air tubes D=3 mm between CPF and spray arm.
  • Check wiring: HVS card to cascade, see the HVS troubleshooting instructions.
  • Measure the voltage with a high-voltage measuring instrument (see the HVS troubleshooting instructions); if the voltage in the electrode is too low, replace the cascade.