421.x Powder: insufficient startup voltage


Description

The minimal cascade voltage could not be reached during start-up of production.

Remedy

  • Clean coating chamber and electrodes.
  • Check the electrode purge air.
  • If there is no purge air: check purge air tubes D=3 mm between CPF and spray arm.
  • Set the high voltage (powder: maximum voltage setpoint) to 40 kV
  • Check wiring: HVS card to cascade, see the HVS troubleshooting instructions.
  • Measure the voltage with a high-voltage measuring instrument (see the HVS troubleshooting instructions); if the voltage in the electrode is too low, replace the cascade.