417.x Powder monitor: signal too high
Description
Powder monitor
 This error is indicated when the mean value of the measurement during calibration is too high. The average exceeds the PccMaxWhiteAverage parameter.
Remedy
- Check whether all can bodies are coated during the setup procedure.
 - Check whether the optical sensor is clean.
 - Check whether the absorption reflector on the OHC is OK.
 - Check whether the pilot light is in the center of the coating (at least 0.5 mm from the edge).
 - Check whether the received coating signal amplitude is correct.
 - Repeat calibration.
 
		