Views:

370.x Vacuum not released


Description

The vacuum has not been switched off. Just before the sheet reaches the first for the two pull-in rollers the vacuum must be switched off. The time is controlled with the "Vacuum off" sensor. If this signal is missing within one machine cycle this fault is triggered.

Remedy

  • Check the "Vacuum off" sensor and re-adjust if necessary.
  • Change the "Vacuum on: Correction angle" by 10° on the GCC drive control page.
  • Check the 'Machine cycle' signal. It should show only one pulse per cycle - re-adjust the machine cycle sensor.
  • Parameter page: "InfeedPulsDuration" must be minimum 160 ms.
  • Check the digital input 

All machine errors