Views:

Fatal error: Attempt to connect a node that doesn't respond


Description

The node with the indicated address (number in brackets) did not respond. 

Remedy

The node has the wrong CAN bus address. Check with the schematic.

The node is not running, see related article: Status indicator of the Unicontrol nodes 

The CAN bus is not running, see related article: Unicontrol x: CAN bus wiring check list 

If UnicontrolConnect (24) is displayed, it is the Pulsar. For standalone systems such as the SWM-3 monitor with integrated Pulsar, the machine must be power cycled via the main switch. 


 

Related Products: UNICONTROL