Views:

Error 347.x Stationary transport / Sensor defective


Description

ONLY WITH DCD: One or more can bodies pass the can-body sensor but no speed
signal (A032 input 1, A032 input 4) is present.

Remedy

  • Do not work in the sensor area while the current is ON.
  • Check setting and function of the speed sensor. Distance to measuring wheel
    should be 0.1-0.3 mm Notch on the sensor’s front part must point to shaft
    direction of measuring wheel.
  • Test cabling and I/O card.

All machine errors