Views:

Error 343.x Monitor: Machine clock has changed


Description

After the Feeder ON signal, the first two machine cycles are not stable. These two cycles must be within 6% of the value measured during last calibration.

Remedy

  • Always calibrate the monitor after production and transport speeds have been changed. 
  • Faults in the machine cycle signal 
  • Feeder switched on too early (before drive has reached production speed). 
  • Check machine cycle sensor in the welding machine and replace if necessary. 
  • Check cabling of sensor to the monitor and correct if necessary. 
  • Replace connector card. 
  • Replace I/O card of energy channel and heat channel if available. 

All machine errors