Error 334.x Setup is required
Description
Production data have not been stored in the monitor This message can come from the energy, heat, powder or pulsar channel. The respective channel is indicated in the error message.
Remedy
- This message can only be removed by activating the monitor setup button!
- Calibrate the monitor if production data have been deleted or if a new monitor has been installed without subsequently running calibration.
- Set up and calibrate the monitor if new software has been loaded without performing a new setup of the monitor.
- Stand-alone SWM2 energy monitor with Pulsar:
- if the message is issued during monitor setup before the first can body is welded: increase the amount of can bodies for setup to 10 on the options page. Repeat monitor setup afterward.
- Disable the channel in the HMI.
- If the error still occurs, create a Can Spy log and inform the Soudronic customer service center.