Error 240.32 Sensor defective
Description
Unicontrol node Reject A032, Divider A033 or QaReject A036 digital input 1
Only with DCD or DCS systems.
The DCD or DCS should eject a can body. However there is no can body present at DCD A032:In1 or DCS A033:In1.
Remedy
- Check sensor and wiring to Qa A014:In1. A second sensor is present for AFB machines.
- Check sensor and wiring to DCD A032:In1.
- Check the GCC parameter “Eject unit: distance between can body and eject unit”. For one sensor: enter 0 mm, for two sensors enter the distance between the sensors.
- Check speed of Larc1, Larc2 and DCD and adjust frequency converter.
- Check the digital input.