Views:

Error 240.32 Sensor defective


Description

Unicontrol node Reject A032, Divider A033 or QaReject A036 digital input 1
Only with DCD or DCS systems.
The DCD or DCS should eject a can body. However there is no can body present at DCD A032:In1 or DCS A033:In1.

Remedy

  • Check sensor and wiring to Qa A014:In1. A second sensor is present for AFB machines. 
  • Check sensor and wiring to DCD A032:In1. 
  • Check the GCC parameter “Eject unit: distance between can body and eject unit”. For one sensor: enter 0 mm, for two sensors enter the distance between the sensors. 
  • Check speed of Larc1, Larc2 and DCD and adjust frequency converter. 
  • Check the digital input

All machine errors