Error 240.14 Sensor defective
Description
Unicontrol node Qa A014 digital input 1
The can-body sensor (A014 Input 1) in
the eject station displays signal level high for a prolonged period of time
after feeder ON.
More than 600 can bodies are waiting in the queue without a
can body being detected.
Remedy
- Align the sensor on the reflector so that LED on sensor lights up constantly. It may be necessary to adjust the potentiometer on the sensor.
- Check sensor and reflector and replace if necessary.
- If the can-body sensor fails during production check cabling and I/O card.
- Check the digital input.