Error 200.x Unisoud/Pulsar: Measured current regulator deviation


Description

The regulator control (contamination) has tripped.
Only for UNISOUD or Pulsar Retro.
Without eject station: machine crash
With eject station: machine is stopped gradually. All subsequent can bodies are ejected.

Remedy

  • Activate the energy channel monitor. 
  • Setup the monitor again. 
  • Check signal reduction monitor. 
  • Remove the contaminated sheet. Check the lacquer margin on the sheet. 
  • Check roller heads, welding transformer, sheet, copper wire and bolts in the primary and secondary circuit. 
  • Check the insulation of the welding transformer and check for short circuit. 
  • Check the Pulsar display; see the instruction manual for help. 
  • Check the digital input