Views:

Error 132.x Trailing end too late


Description

The trailing end of a can body was detected 37.5% later relatively to the set-up process. (37.5% relate to the throughput time when the can body passes by the sensor B91).

Remedy

  • Set ejector and sensors correctly according to the Instruction Manual. 
  • Sensor LED must not flash in passive state. ==> Adjust sensor and clean or replace reflector. 
  • Set up the monitor after every change of the operating parameters (can-body height, transport lengths, can-body gap). 
  • Check can body flow. Do not speed up can body at sensor. 
  • Test can-body sensor and connection to the UNICONTROL node and replace if necessary. 
  • Check the digital input
  • Feeder ON signal in monitor box (X12) is missing. 

All machine errors