Error 126.x Conveyor 3 bottom disengaged
Description
Additional infeed unit for conveyor 3
For undersquare can bodies an additional conveyor 3 infeed unit can be used. This infeed unit is dynamically detected via a sensor. If within 1.5 machine cycles a signal is not received from this infeed unit, this message will be displayed. If there is a fault when pushing into position the third infeed unit will be disengaged.
Remedy
- Third feed system engaged again.
- Deselect the feed on the GCC.
- Check the digital input.