Views:

Error 68.x Burner not lit


Description

Error description...

Remedy

  • No sparks, clean the spark plug, check the electrode distance, maximum 3-4 mm. 
  • Check the ignition transformer, ground contact, plug. 
  • If the ignition control is defective/replace it. 
  • Check the flame monitor, check the monitoring electrode. 
  • Check the zero-pressure regulator (applies for systems with pressure regulators). 
  • LEDs light up on the safety valves of the mixer upon ignition. (applies for systems with pressure-regulators). 
  • Check primary pressure (gas) (3 m burner 10 to 70 mbar, 1.5 m burner 7 to 90 mbar). 
  • Check secondary air pressure (3 m burner per 1.5 mmWs, 1.5 m burner per 3 mm wg). 
  • Check the oven ready signal. 
  • The application software for burner controls with Honeywell DKG 972 N must be from February 2017. 

All machine errors