Error 68.x Burner not lit
Description
Error description...
Remedy
- No sparks, clean the spark plug, check the electrode distance, maximum 3-4 mm.
 - Check the ignition transformer, ground contact, plug.
 - If the ignition control is defective/replace it.
 - Check the flame monitor, check the monitoring electrode.
 - Check the zero-pressure regulator (applies for systems with pressure regulators).
 - LEDs light up on the safety valves of the mixer upon ignition. (applies for systems with pressure-regulators).
 - Check primary pressure (gas) (3 m burner 10 to 70 mbar, 1.5 m burner 7 to 90 mbar).
 - Check secondary air pressure (3 m burner per 1.5 mmWs, 1.5 m burner per 3 mm wg).
 - Check the oven ready signal.
 - The application software for burner controls with Honeywell DKG 972 N must be from February 2017.
 
		