Error 55.x Wire break in wire loop
Description
Profiler
The wire compensator of the profiler has reached a stop. This stop is also reached when the wire is torn.
Remedy
- Check wire path.
- Check pressure of wire profiler compensator.
- Check the basic mechanical settings of the analog sensor.
- Check the electric release signal on the frequency converter.
- Check the pneumatic cylinder.
- Check the digital input.