Error 35.x Welding transformer too hot
Description
The temperature of the welding transformer is too high.
The primary side has a temperature in excess of 130 degrees Celsius or the secondary side has a temperature greater than 60 degrees Celsius.
Remedy
- Check the transformer cooling.
- Check the temperature switch.
- Check the cooling boring for furring and decalcify if necessary.
- Check the threaded unions of the primary and secondary connections.
- Check the digital input.