Exchange of Pacemaker HF


How To:

  1. Switch off cooling unit.
     
  2. Switch off main power. Wait 10 min until the capacitors inside Pacemaker HF are discharged before removing cover.
     
  3. Before you remove any cable, take some picture and note how they are connected.
     
  4. Disconnect the cables and water tubes on the c-bank.
     
  5. Disconnect the power cable and the water tubes on Pacemaker HF unit.
     
  6. Disconnect the signal cable (Plug Sub D 25 Pin) and the panel cable (Plug Sub D 9 Pin).
     
  7. Disconnect the two valve cables inside Pacemaker HF.
     
  8. Remove the Pacemaker HF and replace with new or spare unit.
     
  9. Reconnect all cables.
     
  10. ATTENTION: Check the coil before connecting it!
  • Coil must be dry.
  • Insulation must be in good condition!
  • All connections inside could must be fixed well.
  • See related article: Sparking on the induction coil! Error: “Output overcurrent”, “CH-driver fault” or “Frequency abnormal”
  1. Double check all connection before switching on the main power.
     
  2. Compare the settings/parameter and change it if necessary. For instructions which parameters has to set and how to do please contact Can Man
     
  3. Re-start the PowerCURE™

 

Related Products: PacemakerHF 10 kW V1, PacemakerHF 10 kW V2, PowerCURE