Sparking on the induction coil! Error: "Output overcurrent", "CH-driver fault" or "Frequency abnormal"


Remedy:

  • Make sure that there is a clearance of 3–5 mm between the coil and the can body!
     
  • Make sure that the cooling water temperatur setting is correct (> 25°C) and you have no condensation at the coil. Condensation could cause a short circuit!

HF filter not set correctly (to high)

  • Check setting of PLL stfreq and HF filter. HF filter must be set 10KHz higher than the PLL stfreq. Go to the “system setup” to check.
          Note: The setting is password protected. If adjustment is needed, please contact Can Man.

Check all insulations of the coil and C-bar.

  • Download PDF (see attachment) for more details!

 