Error 342.x Monitor: speed changed


Description

The welding machine production is no longer the same as it was during calibration. The cycle time has changed by ±6%.
A machine cycle error has occurred.

Remedy

Always calibrate the monitor after production and transport speeds have been changed.

  • Calibrate the monitor. 
  • Welding current must be switched on before switching the feeder on. 
  • Check wiring. 

Faults in the machine cycle signal

  • Check that timing disk fits tightly. 
  • Check and adjust machine cycle sensor. 
  • In case of FAEL LSP machines, the first can body is delayed. Set potentiometer P1+. 
  • If signal is disturbed by electromagnetic effect, measure with oscilloscope. Malfunctions can be caused by contactor coils without interference suppression. 
  • Record CAN Spy after the error has occurred and analyze the machine cycle signal. 

 