Error 103.x Monitor: too many samples


Description

The number of measuring points between two machine cycle pulses has changed excessively while production is in progress. Deviation >6%

This monitoring is used to remind the operator to do a new calibration after the production speed or the frequency has changed. 

But a more important reason is: That the fault is triggered if the machine cycle signal is faulty. 

  • If during one machine cycle two or more clock pulses appeared. In this case the monitor gets out of synchronization and start rejecting the wrong cans.
  • If one machine cycle is missing.

Remedy

  • After every change of the production parameters (welding frequency or production rate), calibrate the monitor again. 
  • If the machine cycle signal has failed, check the machine cycle signal and current path. 
  • If machine cycle signal coincides with the can-body leading end, adjust position of switching disk by a few degrees. 
  • In the event of fluctuations in the welding current frequency, measure the frequency. 
  • Soucan 100, AFB 100 with can-body sensor before welding plane:
    • in case of slippage differences the can body welding takes longer This leads to different can-body gaps. Check the cut blanks and compare the length of the tin mark with the can-body height (max. 2.5%).