Error 5.x Flow rate too low / Water pump switched off


Description

A cooling circuit has fallen below the minimum flow rate. The measured values are shown on the GCC “Cooling water” page.

Remedy

  • Open the cooling water valve. 
  • Check water inlet pressure. 
  • Clean the cooling water filter. 
  • Check the sensor (turbine) and clean or replace. 
  • Check the cooling water lines. 
  • Reduce the cooling water flow in the GCC. 
  • Discon cooling: the minimum flow rate can be reduced for all AFB/FBB 100...1000 machines with serial cooling.
  • Set parameter $CoolingCircuitMinForDisconIsReduced = TRUE. 
  • Check the digital input.