Abstract
Step by step instruction on how to setup the tension measuring sensor on the new wire system S.
Summary
Setup of the tension measuring sensor on the wire system S.
Attention: Usually there are two sensor built into the system. Sensor after the profiling unit and before the wire chopper.
Cause
Sensor of tension measurement device has been replaced
Setting of sensor got lost or wire system not working properly
Preconditions
Mounting block of tension measurement still factory aligned (if not please contact customer support)
Original sensor used for measuring the distance
Only qualified staff allowed for setup of the wire tension sensor
Remedy
Mechanical setup of sensor (between sensor and flexure hinge)
Set distance between sensor and flexure hinge to:
0.5mm ±0.05
Tighten with nut. Make sure distance stays the same after fixation.Preparation for teach process
No wire pulled in
Magnet ready for teach process
Teach process of sensor
1-point teach analog: compensation for installation tolerances (see attached video)Hold the magnet to the sensor (>2 sec.) until the LED blinks at 2 Hz.
Place the object (in this case the flexure hinge) at teach position
Briefly tap the sensor with the magnet
Wait 4 seconds until the LED goes out
Result
Sensor teached.
Remark:
Factory setting of sensor in case of wrong teaching process:
Hold magnet to the Sensor longer than 6 seconds until LED blinks with 8Hz.