Views:

Unstable double sheet measurement


Summary

The sheet is lifted by the front sucker bar but then dropped instead of being pushed into table 1. After 3 times slitter stop and error message “SEPARATION: Double sheet counter limit” appears

Remedy

    1. Check on the HMI whether the correct sheet thickness values has been set.
    2. Check whether the sheets are sticking to each other or not. If they do, separate the top ones physically from each other and try again to destack them.
    3. Check the position / correct function of all separation air nozzles left and right: The top sheets should be visually separated.
    4. Check the position / correct function of all separation magnets left and right: The top sheets should be visually separated.
    5. If available switch on the separating air between downstacker and 1. table as well, and reset their height if necessary.
    6. Check the physical setting height of the double sheet sensor: If the sensor is set too high, he will not be in contact with the sheet, resulting in incorrect measurements.
    7. Check the cable between double sheet sensor and control. There may be a cable break which influences the measurement result. Replace the cable if needed.

     

     

    Related Products: PowerCUT