Views:

Incorrect error code on seven segment display


Summary

The seven segment display shows an incorrect error code.

Cause 

  • Interface defective
  • Outputs on card A109 defective
  • Problems with the wiring

Remedy

The following test can be used to verify that the A109 output board is working properly. Follow the error up to the seven-segment display.

    1.  Generate a known error.
    2.  Check the outputs on card A109. A40 to A45. 
      • A40 to A42 correspond to the first digit on the dsiplay.
      • A43 to A45 correspond to the second digit on the display.
    3.  Define the error number using the table below.
    • Example of error 70 (emergency stop)  
    • Example of error 56 

     

     

    Related Products: Control 1000