Incorrect error code on seven segment display
Summary
The seven segment display shows an incorrect error code.
Cause
- Interface defective
- Outputs on card A109 defective
- Problems with the wiring
Remedy
The following test can be used to verify that the A109 output board is working properly. Follow the error up to the seven-segment display.
- Generate a known error.
- Check the outputs on card A109. A40 to A45.
- A40 to A42 correspond to the first digit on the dsiplay.
- A43 to A45 correspond to the second digit on the display.
- Define the error number using the table below.
- Example of error 70 (emergency stop)
- Example of error 56