Views:

Error Message: "One phase missing"


Summary:

The Pacemaker™ HF has detected a missing phase.
 

Causes:

  • Supply voltage mains (all three phases) 400V
     
  • Check the small fuses on the bottom of Pacemaker HF
     
  • Check complete wiring, Are all clamps tightened?
     
  • Measuring voltage at the input terminals on the main board (see attached picture)
     
  • IC “OC14” or phase measurement is defective. Replace the IC, Type HCPL3700
Related Products: PowerCURE, PowerCURE EAR