Views:

Motor push finger does not start. Motor tries to move but stops immediately. Servo-controller shows error P03.


P03 = positioning countering error

Cause:

  • Resolver on the backside of the body transport motor is damaged.
    • Check if the bearings are worn out!
       
  • Resolver is not fixed well on the shaft.
    • Fix it!
       
  • Wire break in the cable between resolver and servo controller.
    • Check the cable!

 

Related Products: CM 16, CM 16 Silentium, X1, X6